FFU EC Mini Type

Description

  • The degree of cleanliness from class 1 up to 100,000 can be set and it can be set in individual areas.
  • Because the back in the ceiling is a low-pressure area, the potential of the leakage is extremely low.
  • Bay method or through-the-wall method is possible by the arrangement of the layout of FFU.
  • The volume of the airflow can be set at each area.
  • Flexible increase or change of the clean room is possible by the arrangement of FFU.
  • Reduce running costs and save energy by using EC brushless frequency converter motor.
  • Customized service available.

  • A. Variable speed turbo fan, low noise level, completely closed type, no dust being generated, special design of the air diversion & air duct to try to decrease the pressure drop & noise level and improve fan static pressure as well.
  • B. Easy maintenance & repair, the control panel has with ON/ OFF switch, indicator lamp, running indicator lamp, failure abnormal indicator lamp, and failure output of a & b dry contact.
  • C. with backward inclined fan impeller, dynamic vibration balance: G2.5.
  • D. Can be monitored and controlled by group controller.
  • E. Can be connected with PLC software via RS485 Modbus protocol.

  • MATERIAL :  SUS430 & AL-Zn
  • POWER :  AC 1Ø 220V 50/60Hz
  • MOTOR :  EC Brushless Frequency Converter Motor
  • HEPA :  Aluminum frame, Filtration efficiency 99.99% at 0.3um
  • (Optional: ULPA 99.999% at 0.1~0.12um)
  • CERTIFICATION :  CE, RoHS, EN1822
  • (Optional: UL, SEMI)
  • OPTIONAL :  Differential pressure module

Item

MAC-SD3i

MAC-SD5i

MAC-SD7i

External Dimension
(mm)

W

303

403

503

D

303

403

503

H

220

210

210

Body Construction

SUS430 & SUS304

HEPA

Feature

Aluminum frame, Filtration efficiency 99.99% at 0.3um (Optional: ULPA 99.999% at 0.1~0.12um)

Size
(mm)

300x300x50

400x400x50

500x500x50

Air Velocity (m/s)

0.35 ~ 0.70

Air Volume (cmm)

2 ~ 4

3 ~ 7

5 ~ 10.5

Power Consumption(W)

25 ~ 42

38 ~ 53

45 ~ 60

Power Supply

AC 1Ø 220V 50/60Hz

Motor

EC brushless frequency converter motor

Total Weight (kg)

9

10

12

Central Monitoring System

BIG AREA PC Group Monitoring System

  • Control the operating, stop, RPM, and monitor the operating/failure status of large quantities of FFU.
  • Collect signals by Gateway.
  • Connect to Gateway, HUB, and PC by Ethernet TCP / IP.
  • Can control a maximum of 96390 units of FFU.
  • Compatible with ACDT's graphic control software.
  • If ACDT's graphic control software is not used, the system can be connected by the RS485 communication interface on FMGC, built-in standard communication protocol Modbus RTU, PLC, HMI, or data collectors, and use commercially available control software such as iFIX, intouch, and WinCC.

SMALL AREA FFU Mini Group Control System

  • LCD screen
  • The User can control and set FFU from the display screen.
  • Monitor the status (RPM, Operating, Failure. Alarm) of FFU in a single unit, as a group, or in a loop (all connected FFU).
  • Control the on/off and adjust air volume of FFU in a single unit, as a group, or in a loop (all connected FFU)
  • Can divide all connected FFU units into multiple groups.
  • Can check FFU alarm code.
  • Built-in buzzer for failure alarm.
  • Can connect to PC through RS485 communication interface and built-in standard Mbodbus RTU communication protocol.
  • 2 sets of built-in signal output, can connect according to requirement (choose two out of three). 
    A. Differential pressure gauge abnormal signal
    B. FMGC Power On
    C. FFU abnormal signal
  • Differential pressure gauge sensor signal input (0-10V or 4-20mA)
  • Can add customized function (differential pressure display).
  • Can connect up to 255 units of FFU.
  • Can connect a maximum of 63 units of FMCG


Differential pressure module (Optional)

Space saving
Performance optimization
Perfect integration of FFU control and differential pressure module

FEATURES

  • Individual LED display for FFU RPM.
  • Individual LED display for differential pressure value.
  • Fan operation status indicator.
  • Differential pressure status indicator.
  • Error code display for abnormal differential pressure.
  • Differential pressure abnormal signal output.
  • FFU abnormal signal output.
  • Combine FFU controller and differential pressure module to save space.
  • Can connect 1~3 fans.
  • Can set alarm value for upper/ lower differential pressure.
  • Optional: RS485 signal transmission.